- Poster presentation
- Open access
- Published:
Comparing the use of PGMI scoring systems used in the UK and Norway to assess the technical quality of screening mammograms: a pilot study
Breast Cancer Research volume 14, Article number: P41 (2012)
Introduction
The UK and Norway use PGMI scoring to critique mammographic image quality (IQ). PGMI comprises categories with associated criteria for determining mammograms Perfect, Good, Moderate, Inadequate. Implementation of PGMI may be variable, subjective and interpreted locally, making accurate comparison of performance across countries difficult. We compared PGMI use in Cambridge and Oslo, determining differences and possible contributory factors, enabling suggestions for future research and practice.
Methods
Digital mammograms from 112 consecutively screened women were sourced in each centre. Test sets were enriched with mammograms from each PGMI category and independently scored by four mammographers, each with â„4 years' experience, using local PGMI. Each image was individually scored P, G, M, or I. Reasons for scoring less than perfect were documented and each mammogram assigned an overall PGMI score. Test sets were exchanged and the process repeated.
Results
Cambridge uses 17 criteria for scoring mammograms less than perfect. Oslo uses similar criteria, but subcategorised, totalling 39 criteria. There is fair agreement (Îș = 0.38) between centres in assigning images as acceptable overall (P, G, M) but poor inter-rater agreement within and between centres in further categorising acceptable mammograms as P, G or M (Îș <2). Most common faults in Oslo were skin folds, and inadequate pectoralis muscle in Cambridge. Most faults overall were on oblique views.
Conclusion
Poor rater agreement and differing faults may be due to the variation in number and interpretation of categories used. Radiographer training may also be an issue. Further research should establish quantitative assessment methods and internationally uniform practice.
Author information
Authors and Affiliations
Rights and permissions
This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Boyce, M., Gullen, R., Parashar, D. et al. Comparing the use of PGMI scoring systems used in the UK and Norway to assess the technical quality of screening mammograms: a pilot study. Breast Cancer Res 14 (Suppl 1), P41 (2012). https://doi.org/10.1186/bcr3296
Published:
DOI: https://doi.org/10.1186/bcr3296