- Poster presentation
- Open access
- Published:
Changes in recall rate, biopsy rate and cancer detection since the introduction of digital mammography
Breast Cancer Research volume 14, Article number: P18 (2012)
Introduction
Analogue mammography is gradually being replaced by digital mammography for breast screening. Digital mammography has been shown to be at least as good as analogue mammography at cancer detection, but the picture regarding other outcomes such as recall rate and biopsy rate is less clear.
Methods
Outcome data from 62,599 routine screening mammograms taken in Greater Manchester between January 2010 and March 2012 were gathered from screening records. Mean recall, biopsy/cytology and cancer detection rates were calculated for analogue and digital screening and compared. After complete conversion to digital screening, the same three measures were obtained on a monthly basis over 2 years. The data were analysed to identify any trends in the measures.
Results
The digital mammography recall rate was 4.69% (2,505/53,444), with analogue significantly lower at 3.58% (328/9,155) (P < 0.001). The digital biopsy/cytology rate was 1.88% (1,005/53,444), with analogue significantly lower at 1.49% (136/9,155) (P = 0.01). The cancer detection rate (per 1,000 screens) was 6.74 (56/9,155) for digital mammography and 6.15 (358/53,444) for analogue; however, this difference was not significant (P = 0.53). The recall rate showed a strong positive correlation with time (r = 0.71, P < 0.001) and the biopsy rate showed a weak positive correlation (r = 0.52 P = 0.011). Cancer detection showed a weak negative correlation with time (r = -0.567 P = 0.05).
Conclusion
The introduction of digital mammography resulted in higher recall and biopsy rates, but no change in cancer detection. Recall and biopsy rates, whilst still well within recommended levels, appear to be increasing since the introduction of digital mammography; this indicates a need for regular monitoring.
Author information
Authors and Affiliations
Rights and permissions
This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Fyall, T., Boggis, C., Astley, S. et al. Changes in recall rate, biopsy rate and cancer detection since the introduction of digital mammography. Breast Cancer Res 14 (Suppl 1), P18 (2012). https://doi.org/10.1186/bcr3273
Published:
DOI: https://doi.org/10.1186/bcr3273