Figure 6 | Breast Cancer Research

Figure 6

From: Detection of breast cancer cells using targeted magnetic nanoparticles and ultra-sensitive magnetic field sensors

Figure 6

Photographs of the breast clay phantom containing two vials of MCF7/HER2-18 cells. (a) The x-z plane with z coordinate in the vertical direction. (b) The x-y plane with the × coordinate along the axis of the ruler. The small black dots (indicated by red arrows) are the 65% confidence limits for determining the positions of the centroid of the cells in the embedded vials. The size of the dots represents the uncertainty in the computed position of the sources. (c) A three-dimensional contour of the emitted magnetic relaxometry fields from the two sources contained in the phantom.